Load Bank Testing
A comprehensive preventive maintenance program is critical to the reliability of a standby generator. Generator load bank testing is an essential part of good maintenance practices. Performing yearly load bank tests helps to extend the generator’s engine life and ensure reliable operation during a utility power failure.
What is Generator Load Bank Testing?
Load bank testing allows a standby generator to be tested and exercised to verify its overall reliability and its ability to run at its full rated KW output. Typically, a generator is running at a level far less than the unit’s rated output capability. Load bank testing checks the engine’s ability to perform and provide the required horsepower when called upon in an emergency. When a load bank is used, the artificial load it provides brings the engine up to an acceptable operating temperature.
What is No-Load Testing?
Most generator owners exercise their standby generators weekly un-loaded, but very rarely test them with building loads, relying on the occasional utility loss to do the testing. For diesel engine driven generator sets, this can cause ‘wet stacking’. Wet stacking is when unburned fuel accumulates in the engine exhaust. This is caused by underloading a generator. When exercising a generator or running it for short duration outages while under loaded, the engine may not reach its optimum operating temperature. When this is allowed to continue for long periods of time the unburned fuel accumulates and can become harmful to the engine’s efficiency and life span.
Serving Michigan, Ohio, and Indiana
Commercial & Industrial Backup Power Solutions.
What are the Benefits?
Load bank testing allows the engine to reach this full operating temperature and ‘burns out’ this accumulation of un-burnt fuel. The result is a unit that runs cleaner and more efficiently. It also offers peace of mind that your standby generator is operating as it was designed to. Any generator set, whether the prime mover is diesel or gaseous fuel driven, can benefit from having it load bank tested.
American Generators' Load Banking Service
During the load bank test an American Generators’ Service Technician monitors critical engine parameters such as: oil pressure, engine temperature, fuel pressure, etc. We record these readings to show that once the unit reaches full rated load, it runs at normal operating temperatures and pressures. With this service American Generators provides a full report of the readings including generator output readings such as: voltages, amperages, KW amounts, etc.
American Generators offers load bank testing as a separate service. We can also structure it into a service contract to make it part of the scheduled, budgeted, yearly maintenance on your standby power system. Load bank testing is in no way intrusive, and during the test there is no interruption to your facility’s loads. Most manufacturers agree, a generator set that is frequently run lightly loaded, or never loaded at all, can benefit from being load banked on a yearly basis.
Why Choose American Generators?
American Generators strives to maximize speed, quality, and affordability in all our services. We offer the most advanced equipment, installing it quickly without cutting corners or overcharging you. Once we’ve installed a generator, we will provide troubleshooting and maintenance service to keep it in good condition.
Choosing the Right Generator for Your Business
We take into account your price range, power needs, fuel sources, and other considerations when installing a generator. Our goal is to provide a backup power source that will meet your full demand without creating any operation issues.
Customer Review
5-Star Customer Review
FAQs about Generator Load Bank Testing in Michigan
What is generator load bank testing?
Generator load bank testing applies an artificial electrical load to a standby generator to verify it can run at its full rated kW output. American Generators Sales & Service uses load bank testing to confirm a generator’s engine can deliver the required horsepower in an emergency and to bring it up to proper operating temperature.
How often should a generator be load bank tested?
Most manufacturers recommend load bank testing a standby generator once a year, especially units that are usually exercised with little or no load. Facilities following NFPA 110 may also need annual load bank testing when monthly tests don’t reach the required load level. American Generators Sales & Service can include yearly load bank testing in a maintenance contract.
What is wet stacking, and how does load bank testing prevent it?
Wet stacking is the buildup of unburned fuel in a diesel generator’s exhaust caused by running the engine underloaded, such as during weekly no-load exercise. Load bank testing brings the engine to full operating temperature and burns off that accumulated fuel, so the generator runs cleaner and more efficiently.
Will load bank testing interrupt power to my facility?
No. Load bank testing by American Generators Sales & Service is non-intrusive and causes no interruption to your facility’s electrical loads. During the test, a technician monitors oil pressure, engine temperature, and fuel pressure, records voltage, amperage, and kW output, and provides a full report of the readings.
Who offers generator load bank testing near me in Michigan?
American Generators Sales & Service provides generator load bank testing for diesel and gaseous-fuel generators across Metro Detroit, Southeast Michigan, Mid-Michigan, and the Thumb, including Oakland, Macomb, Wayne, Washtenaw, Genesee, Livingston, Saginaw, Bay, Midland, Ingham, Jackson, and Monroe County. Call (248) 623-4919 to schedule a test.